Product Center
-
Hydrological equipment monitoring station
-
Water Quality Monitor Sensor
-
Plant protection equipment
-
Food Testing Equipment
- Automatic Soil Moisture Monitors Enabling Low-Power, Long-Term Field Monitoring
- Smart Termite Monitoring Gateway Achieves Stable Networking in Complex Field Environments Through Multi-Protocol Design
- Potato late blight monitor Built-in Early Warning Model Automatically Calculates Disease Incidence Probability
- Termite Monitoring and Control System Enhancing Efficiency in Levee Termite Infestation Surveys via AI Recognition
- Real-time Locust Monitoring and Early Warning Station Automated Imaging and Identification of Locust Species and Density
- IoT System for Lake Water Monitoring: Real-time Data Collection and Transmission
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Tel, Whatsapp:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Ammonia Nitrogen Sensor
Model:FT-SS5
Brand:fengtu
Product details
1. Product introduction of Ammonia Nitrogen Sensor
Ammonia Nitrogen Sensor is not only applicable to the field and on-site rapid water ammonia nitrogen emergency detection, but also suitable for laboratory water ammonia nitrogen analysis.SS5 model Ammonia Nitrogen Sensor is an electrode method water quality analysis instrument that uses fully digital electrode detection to detect water quality ammonia nitrogen and PH parameters.The instrument is equipped with the self-developed ftiot operating system, which is simple to operate, has stable performance, accurate measurement, and wide detection range.It has a built-in high-capacity rechargeable lithium battery, making it convenient for users to conduct water quality testing at any time in the field or laboratory.
2.Ammonia Nitrogen Sensor host parameters
| Charging input voltage | 4.5V-5.5V |
| Charging current | <2A |
| screen size | 3.5 inches |
| screen resolution | 480*800☆ |
| screen interface | MIPI DSI☆ |
| USB interface | 2 (Supports external expansion of mouse, keyboard, 4G, etc.)☆ |
| Type-C | 1 (Supports external expansion of mouse, keyboard, 4G, etc.)☆ |
| RS485 | 2 (Supports Modbus, json, asc input, etc.) |
| External sensor supply voltage | 12V |
| External sensor supply current | 1A |
| operating system | ftiot (based on Linux-5.4)☆ |
| CPU | 2*Cotex-A7, 650Mhz☆ |
| RAM | 512M DDR3☆ |
| Flash | 8G-64G |
| OpenGL | ES 2.0☆ |
| Wifi | support |
| 4G | Optional |
| button | support |
| capacitive touch screen | support |
| software architecture | B/S☆ |
| web access | Support☆ |
| MTP mode | Support☆ |
| Multiple terminal login | Support☆ |
| IPV6 | Support☆ |
| Sensor communication method | RS485, TCP, UDP, HTTP☆ |
| Data forwarding method | RS485, TCP, UDP, HTTP☆ |
| Remote SSH | Support☆ |
| remote debugging | Support☆ |
3.Ammonia Nitrogen Sensor sensor parameters and configuration
| serial number | name | Measuring range | principle | Measurement accuracy | Configuration | Remark |
| 1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | ||
| 2 | pH | 0~14(ph) | Electrochemistry (Salt Bridge) | ±0.1PH | ✔ | |
| 3 | ORP | -1500mv~1500mv | Electrochemistry (Salt Bridge) | ±6mv | ||
| 4 | Conductivity | 0~5000uS/cm,0~10000uS/cm | contact electrode method | ±1.5% | ||
| 5 | TDS | 0~20μS/cm (TDS 0-10mg/L) | contact electrode method | ±1.5% | ||
| 6 | salinity | 0-2.5ppt or 0-80ppt | contact electrode method | ±0.05ppt or ±1ppt | ||
| 7 | Sludge concentration | 0~20.000g/L | scattered light method | ±5% (depending on sludge homogeneity) | ||
| 8 | Turbidity | 0~40NTU (low turbidity) | scattered light method | ±1% | Optional | |
| 0~1000NTU (medium turbidity) | scattered light method | ±1% | ||||
| 0~3000NTU (high turbidity) | scattered light method | ±1% | ||||
| 9 | Dissolved oxygen | 0~20mg/L | fluorescence lifetime method | ±2% | ||
| 10 | Ammonia nitrogen | 0-1000.00mg/L (default) 0-100.00mg/l/ (customizable) | Ion selective electrode method | 10% of reading, ±0.5℃ | ✔ | |
| 11 | suspended solids | 0~2000mg/L | scattered light method | ±5% (depending on sludge homogeneity) | ||
| 12 | Residual chlorine | 0~5.00mg/L | Ion selective electrode method | ±5% of reading | The accuracy is best when the flow rate is 0.42m/s-0.85m/s. | |
| 13 | Chloride ions | 0-3500.0mg/L | Ion selective electrode method | ±5% | ||
| 14 | Total hardness | 0~1000.0mg/L | Ion selective electrode method | ±10% of reading | ||
| 15 | cod | 0~500mg/L | UV254 absorption method | ±5% | COD and chlorophyll are equipped with automatic cleaners to prevent biological adhesion and avoid light window pollution to ensure long-term monitoring is still stable; the automatic cleaning time and cleaning frequency can be set, and the power consumption is 0.7W | |
| 16 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 |
This paper addresses:https://fengtusz.com/Portable-Water-Quality-Monitor/Ammonia-Nitrogen-Sensor.html
- Previous Article :Dissolved oxygen meter
- Next Article:COD Analyzer
Related article
-
Agro-meteorological station configuration
2024-04-02 -
Soil moisture monitoring station Field Rapid Deployment Monitoring of Soil Moisture, Temperature, and Electrical Conductivity
2026-02-03 -
Seismic Aftershock Monitoring System FT-YZ2: Features and Applications in Disaster Prevention
2025-05-08 -
FT-TS200 Automatic Soil Monitoring System: Precision Multi-Point Soil Moisture Measurement for Smart Agriculture
2025-05-23 -
Rainfall Monitoring Station: Indispensable Tool for Rainfall Observation and Agricultural Meteorological Services
2025-09-10 -
FT-LS5+ Hand-Held Radar Current Meter: Enabling Safe and Non-Contact Flow Measurement
2025-11-12 -
Significance of Soil pH Detection and Innovation of FT-TP1 Rapid Tester
2025-06-10 -
Pole - Mounted Water Quality Monitoring Stations: Key Parameters, Models by Fengtu and Their Significance
2025-04-11


Get a Free Quote






