Product Center
-
Hydrological equipment monitoring station
-
Water Quality Monitor Sensor
-
Plant protection equipment
-
Food Testing Equipment
- Automatic Soil Moisture Monitors Enabling Low-Power, Long-Term Field Monitoring
- Smart Termite Monitoring Gateway Achieves Stable Networking in Complex Field Environments Through Multi-Protocol Design
- Potato late blight monitor Built-in Early Warning Model Automatically Calculates Disease Incidence Probability
- Termite Monitoring and Control System Enhancing Efficiency in Levee Termite Infestation Surveys via AI Recognition
- Real-time Locust Monitoring and Early Warning Station Automated Imaging and Identification of Locust Species and Density
- IoT System for Lake Water Monitoring: Real-time Data Collection and Transmission
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Tel, Whatsapp:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Dissolved oxygen meter
Model:FT-SS8
Brand:fengtu
Related products
Product details
1. Product introduction of Dissolved oxygen meter
Dissolved oxygen meter is widely used in dissolved oxygen detection in aquaculture, sewage treatment, rice field water quality, environmental monitoring and other industries.SS8 model Dissolved oxygen meter is an electrode method water quality analysis instrument that uses fully digital electrode detection to detect dissolved oxygen parameters.The instrument is equipped with the self-developed ftiot operating system, which is simple to operate, has stable performance, accurate measurement, and wide detection range.It has a built-in high-capacity rechargeable lithium battery, making it convenient for users to conduct water quality testing at any time in the field or laboratory.
2.Dissolved oxygen meter host parameters
| Charging input voltage | 4.5V-5.5V |
| Charging current | <2A |
| screen size | 3.5 inches |
| screen resolution | 480*800☆ |
| screen interface | MIPI DSI☆ |
| USB interface | 2 (Supports external expansion of mouse, keyboard, 4G, etc.)☆ |
| Type-C | 1 (Supports external expansion of mouse, keyboard, 4G, etc.)☆ |
| RS485 | 2 (Supports Modbus, json, asc input, etc.) |
| External sensor supply voltage | 12V |
| External sensor supply current | 1A |
| operating system | ftiot (based on Linux-5.4)☆ |
| CPU | 2*Cotex-A7, 650Mhz☆ |
| RAM | 512M DDR3☆ |
| Flash | 8G-64G |
| OpenGL | ES 2.0☆ |
| Wifi | support |
| 4G | Optional |
| button | support |
| capacitive touch screen | support |
| software architecture | B/S☆ |
| web access | Support☆ |
| MTP mode | Support☆ |
| Multiple terminal login | Support☆ |
| IPV6 | Support☆ |
| Sensor communication method | RS485, TCP, UDP, HTTP☆ |
| Data forwarding method | RS485, TCP, UDP, HTTP☆ |
| Remote SSH | Support☆ |
| remote debugging | Support☆ |
3.Dissolved oxygen meter sensor parameters and configuration
| serial number | name | Measuring range | principle | Measurement accuracy | Configuration | Remark |
| 1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | ||
| 2 | pH | 0~14(ph) | Electrochemistry (Salt Bridge) | ±0.1PH | ||
| 3 | ORP | -1500mv~1500mv | Electrochemistry (Salt Bridge) | ±6mv | ||
| 4 | Conductivity | 0~5000uS/cm,0~10000uS/cm | contact electrode method | ±1.5% | ||
| 5 | TDS | 0~20μS/cm (TDS 0-10mg/L) | contact electrode method | ±1.5% | ||
| 6 | salinity | 0-2.5ppt or 0-80ppt | contact electrode method | ±0.05ppt or ±1ppt | ||
| 7 | Sludge concentration | 0~20.000g/L | scattered light method | ±5% (depending on sludge homogeneity) | ||
| 8 | Turbidity | 0~40NTU (low turbidity) | scattered light method | ±1% | Optional | |
| 0~1000NTU (medium turbidity) | scattered light method | ±1% | ||||
| 0~3000NTU (high turbidity) | scattered light method | ±1% | ||||
| 9 | Dissolved oxygen | 0~20mg/L | fluorescence lifetime method | ±2% | ✔ | |
| 10 | Ammonia nitrogen | 0-1000.00mg/L (default) 0-100.00mg/l/ (customizable) | Ion selective electrode method | 10% of reading, ±0.5℃ | ||
| 11 | suspended solids | 0~2000mg/L | scattered light method | ±5% (depending on sludge homogeneity) | ||
| 12 | Residual chlorine | 0~5.00mg/L | Ion selective electrode method | ±5% of reading | The accuracy is best when the flow rate is 0.42m/s-0.85m/s. | |
| 13 | Chloride ions | 0-3500.0mg/L | Ion selective electrode method | ±5% | ||
| 14 | Total hardness | 0~1000.0mg/L | Ion selective electrode method | ±10% of reading | ||
| 15 | cod | 0~500mg/L | UV254 absorption method | ±5% | COD and chlorophyll are equipped with automatic cleaners to prevent biological adhesion and avoid light window pollution to ensure long-term monitoring is still stable; the automatic cleaning time and cleaning frequency can be set, and the power consumption is 0.7W | |
| 16 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 |
This paper addresses:https://fengtusz.com/Portable-Water-Quality-Monitor/Dissolved-oxygen-meter.html
- Previous Article :Portable Turbidimeter
- Next Article:Ammonia Nitrogen Sensor
Related article
-
Agri-weather stations are important
2024-03-22 -
High-altitude detection lamps defend against pest threats
2024-04-16 -
Crop Monitoring and Scouting Integrated Online Monitoring System for Soil Moisture, Pest Activity, Crop Growth, Disaster Conditions, and Spores
2026-03-24 -
High-Performance GNSS Receivers for Precision Positioning and Displacement Measurement" Chinese
2025-10-28 -
What is the approximate weight and size of the current water quality monitoring buoys?
2024-05-27 -
Water quality monitoring stations to protect lake resources
2024-06-19 -
Weather stations for transmission lines to prevent power supply obstacles to disasters
2024-05-09 -
Forest weather stations improve forest fire prevention
2024-03-07


Get a Free Quote