Dissolved oxygen meter

Dissolved oxygen meter

Model:FT-SS8

Brand:fengtu

Dissolved oxygen meter is widely used in dissolved oxygen detection in aquaculture, sewage treatment, rice field water quality, environmental monitoring and other industries.

Product details

1. Product introduction of Dissolved oxygen meter

Dissolved oxygen meter is widely used in dissolved oxygen detection in aquaculture, sewage treatment, rice field water quality, environmental monitoring and other industries.SS8 model Dissolved oxygen meter is an electrode method water quality analysis instrument that uses fully digital electrode detection to detect dissolved oxygen parameters.The instrument is equipped with the self-developed ftiot operating system, which is simple to operate, has stable performance, accurate measurement, and wide detection range.It has a built-in high-capacity rechargeable lithium battery, making it convenient for users to conduct water quality testing at any time in the field or laboratory.

2.Dissolved oxygen meter host parameters

Charging input voltage4.5V-5.5V
Charging current<2A
screen size3.5 inches
screen resolution480*800☆
screen interfaceMIPI DSI☆
USB interface2 (Supports external expansion of mouse, keyboard, 4G, etc.)☆
Type-C1 (Supports external expansion of mouse, keyboard, 4G, etc.)☆
RS4852 (Supports Modbus, json, asc input, etc.)
External sensor supply voltage12V
External sensor supply current1A
operating systemftiot (based on Linux-5.4)☆
CPU2*Cotex-A7, 650Mhz☆
RAM512M DDR3☆
Flash8G-64G
OpenGLES 2.0☆
Wifisupport
4GOptional
buttonsupport
capacitive touch screensupport
software architectureB/S☆
web accessSupport☆
MTP modeSupport☆
Multiple terminal loginSupport☆
IPV6Support☆
Sensor communication methodRS485, TCP, UDP, HTTP☆
Data forwarding methodRS485, TCP, UDP, HTTP☆
Remote SSHSupport☆
remote debuggingSupport☆

3.Dissolved oxygen meter sensor parameters and configuration

serial numbernameMeasuring rangeprincipleMeasurement accuracyConfigurationRemark
1temperature0~50℃High-precision digital sensor±0.3℃

2pH0~14(ph)Electrochemistry (Salt Bridge)±0.1PH

3ORP-1500mv~1500mvElectrochemistry (Salt Bridge)±6mv

4Conductivity0~5000uS/cm,0~10000uS/cmcontact electrode method±1.5%

5TDS0~20μS/cm (TDS 0-10mg/L)contact electrode method±1.5%

6salinity0-2.5ppt or 0-80pptcontact electrode method±0.05ppt or ±1ppt

7Sludge concentration0~20.000g/Lscattered light method±5% (depending on sludge homogeneity)

8Turbidity0~40NTU (low turbidity)scattered light method±1%
Optional
0~1000NTU (medium turbidity)scattered light method±1%
0~3000NTU (high turbidity)scattered light method±1%
9Dissolved oxygen0~20mg/Lfluorescence lifetime method±2%
10Ammonia nitrogen0~100mg/lIon selective electrode method±1mg

11suspended solids0~2000mg/Lscattered light method±5% (depending on sludge homogeneity)

12Residual chlorine0~5.00mg/LIon selective electrode method±5% of reading
The accuracy is best when the flow rate is 0.42m/s-0.85m/s.
13Chloride ions0-3500.0mg/LIon selective electrode method±5%

14Total hardness0~1000.0mg/LIon selective electrode method±10% of reading

15cod0~500mg/LUV254 absorption method±5%
COD and chlorophyll are equipped with automatic cleaners to prevent biological adhesion and avoid light window pollution to ensure long-term monitoring is still stable; the automatic cleaning time and cleaning frequency can be set, and the power consumption is 0.7W
16Chlorophyll0~400ug/LFluorescence methodR2>0.999