Product Center
-
Hydrological equipment monitoring station
-
Water Quality Monitor Sensor
-
Plant protection equipment
-
Food Testing Equipment
- Radar Flow Meter Non-Contact Remote Sensing System for Open Channel Flow
- Automatic Monitoring and Identification Technology for Locusts Attracted by Light and Sex Traps
- Groundwater level monitoring equipment: Precise Measurement of Deep Well Water Levels
- Intelligent monitoring device for forest pests and diseases Accurately Captures Insect Data
- Termite Baiting Systems Real-Time Termite Activity Monitoring System
- Soil moisture monitoring station Field Rapid Deployment Monitoring of Soil Moisture, Temperature, and Electrical Conductivity
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Tel, Whatsapp:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Dissolved oxygen meter
Model:FT-SS8
Brand:fengtu
Related products
Product details
1. Product introduction of Dissolved oxygen meter
Dissolved oxygen meter is widely used in dissolved oxygen detection in aquaculture, sewage treatment, rice field water quality, environmental monitoring and other industries.SS8 model Dissolved oxygen meter is an electrode method water quality analysis instrument that uses fully digital electrode detection to detect dissolved oxygen parameters.The instrument is equipped with the self-developed ftiot operating system, which is simple to operate, has stable performance, accurate measurement, and wide detection range.It has a built-in high-capacity rechargeable lithium battery, making it convenient for users to conduct water quality testing at any time in the field or laboratory.
2.Dissolved oxygen meter host parameters
| Charging input voltage | 4.5V-5.5V |
| Charging current | <2A |
| screen size | 3.5 inches |
| screen resolution | 480*800☆ |
| screen interface | MIPI DSI☆ |
| USB interface | 2 (Supports external expansion of mouse, keyboard, 4G, etc.)☆ |
| Type-C | 1 (Supports external expansion of mouse, keyboard, 4G, etc.)☆ |
| RS485 | 2 (Supports Modbus, json, asc input, etc.) |
| External sensor supply voltage | 12V |
| External sensor supply current | 1A |
| operating system | ftiot (based on Linux-5.4)☆ |
| CPU | 2*Cotex-A7, 650Mhz☆ |
| RAM | 512M DDR3☆ |
| Flash | 8G-64G |
| OpenGL | ES 2.0☆ |
| Wifi | support |
| 4G | Optional |
| button | support |
| capacitive touch screen | support |
| software architecture | B/S☆ |
| web access | Support☆ |
| MTP mode | Support☆ |
| Multiple terminal login | Support☆ |
| IPV6 | Support☆ |
| Sensor communication method | RS485, TCP, UDP, HTTP☆ |
| Data forwarding method | RS485, TCP, UDP, HTTP☆ |
| Remote SSH | Support☆ |
| remote debugging | Support☆ |
3.Dissolved oxygen meter sensor parameters and configuration
| serial number | name | Measuring range | principle | Measurement accuracy | Configuration | Remark |
| 1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | ||
| 2 | pH | 0~14(ph) | Electrochemistry (Salt Bridge) | ±0.1PH | ||
| 3 | ORP | -1500mv~1500mv | Electrochemistry (Salt Bridge) | ±6mv | ||
| 4 | Conductivity | 0~5000uS/cm,0~10000uS/cm | contact electrode method | ±1.5% | ||
| 5 | TDS | 0~20μS/cm (TDS 0-10mg/L) | contact electrode method | ±1.5% | ||
| 6 | salinity | 0-2.5ppt or 0-80ppt | contact electrode method | ±0.05ppt or ±1ppt | ||
| 7 | Sludge concentration | 0~20.000g/L | scattered light method | ±5% (depending on sludge homogeneity) | ||
| 8 | Turbidity | 0~40NTU (low turbidity) | scattered light method | ±1% | Optional | |
| 0~1000NTU (medium turbidity) | scattered light method | ±1% | ||||
| 0~3000NTU (high turbidity) | scattered light method | ±1% | ||||
| 9 | Dissolved oxygen | 0~20mg/L | fluorescence lifetime method | ±2% | ✔ | |
| 10 | Ammonia nitrogen | 0-1000.00mg/L (default) 0-100.00mg/l/ (customizable) | Ion selective electrode method | 10% of reading, ±0.5℃ | ||
| 11 | suspended solids | 0~2000mg/L | scattered light method | ±5% (depending on sludge homogeneity) | ||
| 12 | Residual chlorine | 0~5.00mg/L | Ion selective electrode method | ±5% of reading | The accuracy is best when the flow rate is 0.42m/s-0.85m/s. | |
| 13 | Chloride ions | 0-3500.0mg/L | Ion selective electrode method | ±5% | ||
| 14 | Total hardness | 0~1000.0mg/L | Ion selective electrode method | ±10% of reading | ||
| 15 | cod | 0~500mg/L | UV254 absorption method | ±5% | COD and chlorophyll are equipped with automatic cleaners to prevent biological adhesion and avoid light window pollution to ensure long-term monitoring is still stable; the automatic cleaning time and cleaning frequency can be set, and the power consumption is 0.7W | |
| 16 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 |
This paper addresses:https://fengtusz.com/Portable-Water-Quality-Monitor/Dissolved-oxygen-meter.html
- Previous Article :Portable Turbidimeter
- Next Article:Ammonia Nitrogen Sensor
Related article
-
Grid-Based Small Automatic Weather Station: Affordable, Flexible, and Rapidly Deployable for Localized Monitoring
2025-05-30 -
Intelligent monitoring device for forest pests and diseases Accurately Captures Insect Data
2026-02-05 -
Automatic Soil Monitoring System: Revolutionizing Agriculture with Intelligent and Sustainable Solutions
2025-01-02 -
Non-Contact Rainfall and Water Level Measurement: The FT-SW2 System’s Application in Diverse Water Environments
2025-05-21 -
Soil Moisture Monitoring System: Real-time Calibrated Sensing for Science-based Sowing Decisions
2025-06-24 -
Online Ammonia - Nitrogen Sensors: Pivotal Tools in Understanding, Measuring and Solving Ammonia - Nitrogen Issues
2025-02-18 -
Water Level Monitoring System: Empowering Precision in Hydrological Monitoring and Flood Prevention
2024-11-29 -
FT-GSZ: IoT-Enabled Water Quality Monitoring System for Secondary Water
2024-11-01


Get a Free Quote