Agricultural weather Station
location:Home>Products>Food Testing Equipment>African Swine Fever Virus>African Swine Fever Virus

Product Center

Contact us

Shandong Fengtu IOT Technology Co., Ltd

Sales Manager:Ms. Emily Wang

Tel, Whatsapp:+86 15898932201

Email:info@fengtutec.com

Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

African Swine Fever Virus

African Swine Fever Virus

Model:FT-CW48H

Brand:fengtu

African Swine Fever Virus was detected by nucleic acid free fluorescent quantitative PCR technology, which only needed to extract pet eye secretions, nasopharyngeal swabs, anal swabs, etc.

Product details

Basic structure of African Swine Fever Virus instrument

African Swine Fever Virus was detected by nucleic acid free fluorescent quantitative PCR technology, which only needed to extract pet eye secretions, nasopharyngeal swabs, anal swabs, etc.African Swine Fever Virus is an instrument for real-time detection of reactions. It mainly consists of a gene amplification thermal cycle system, a fluorescence real-time detection system, a microcircuit control system, a computer and application software. Two of the core functional modules are: thermal circulation system and fluorescence real-time detection system. The working principle of the gene amplification thermal cycle system is basically the same as that of the traditional gene amplification instrument. It uses semiconductor heating and cooling to complete the thermal cycle process. The fluorescence detection system mainly consists of fluorescence excitation components, optical signal transmission components, fluorescence detection components, and control systems.

African Swine Fever Virus Instrument Technical Specifications

The "///" symbol indicates that the national standard currently does not define this indicator or mandatory requirement.

Indicator nameCW16HCW32HCW48H
Appearance
Overall dimensions235mm*385mm*175mm (width*depth*height)
weight5.6kg5.7kg5.8Kg
Electrical parameters~220V/50Hz, 255W
Data interfaceUSB 2.0 *2 (two on the right)
Environmental parameters
Operating conditionsTemperature: 10-30℃, humidity: 20%~80%
Shipping and storage conditionsTemperature: -20~55℃, humidity: 20%~80%
altitude<2500 meters
Noise levelA-weighted, <60dB
Sample parameters
sample size16*0.2mL32*0.2mL48*0.2mL
Test tube typeSingle tube, eight row test tubes
sample volume15-100uL
Temperature characteristics
Heating/cooling methodSemiconductor heating/cooling
temperature range4℃-99℃
Maximum heating rate≥3.5℃/s
average heating rate≥2.5℃/s
Maximum cooling rate≥3.5℃/s
average cooling rate≥2.5℃/s
Temperature control accuracy≤±0.01℃
Temperature accuracy≤±0.1℃
temperature uniformity≤±0.3℃
Optical properties
Number of fluorescence detection channels4 channels
Light emitting deviceHigh brightness LED
lighting devicesHigh sensitivity, high signal-to-noise ratio photodiode
Adapter probe or dyeFirst channel: 470/520 FAM, SYBR Green
Second channel: 530/570 HEX, JOE, VIC
Third channel: 580/610 ROX, CY3.5, Texas-Red
Fourth channel: 630/670 CY5
Detection sensitivity1 copy
Linear detection range100~1010 copies
linear correlation coefficient≥0.999
Channel crosstalkNo crosstalk
Test repeatability≤1.0%

Main application fields of African Swine Fever Virus instrument

Foodborne pathogen detection

food safety

Animal and plant origin testing

Plant Science and Agricultural Biotechnology

Gene mutations and polymorphisms

animal diseases

basic scientific research

water body monitoring

Pathogen nucleic acid detection

GMO testing

Animal epidemic surveillance

Food hygiene and quarantine

Customs import and export quarantine



本文地址:https://fengtusz.com/African-Swine-Fever-Virus/African-Swine-Fever-Virus.html
Hello, my friend!What kind of support do you need? Our products is sure to satisfy you.
*Name
*Email
Phone
Country
*Message