Product Center
-
Hydrological equipment monitoring station
-
Water Quality Monitor Sensor
-
Plant protection equipment
-
Food Testing Equipment
- Analysis of the Function and Advantage of Fengtu's Soil Moisture Monitoring Equipment in Drought Resistance
- Water Quality Monitor: The Core Instrument for Assessing and Safeguarding Water Resources
- Soil Moisture Sensor: Precise Installation for Reliable Soil Moisture Monitoring
- Rice Blast Monitor: A Breakthrough in Precise Monitoring and Control of Rice Blast Disease
- School weather station: A Valuable Educational Tool in School
- Revolutionizing Water Quality Monitoring: From Traditional to Advanced Sensors
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Tel, Whatsapp:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Water Hardness Tester
Model:FT-GL02
Brand:fengtu
Related products
Product details
1. Water Hardness Tester Product Introduction
Water Hardness Tester is used to test the total hardness of water quality of boiler feed water and softening water. It is accurate, fast, stable and easy to operate.GL02 Online Water Hardness Tester is an instrument that can monitor the total hardness and chloride ion of water quality online. It integrates water hardness sensor, chloride ion sensor and measurement module communication storage, and can quickly and accurately record key parameters in water bodies. At the same time, the instrument supports the expansion of water quality multi-parameter sensors, including but not limited to pH value, dissolved oxygen (DO), conductivity, turbidity, temperature, ammonia nitrogen, etc., which can be combined and configured according to different needs and applications, record and store historical monitoring data, alarm history records, and support historical data export.xlsx. The RS485 interface supports MODBUS-RTU communication protocol to facilitate users to communicate freely with PLC, DCS, configuration software, DTU and other devices to connect and transmit data.
2. Application fields of Water Hardness Tester
Online Water Hardness Tester is widely used in monitoring and controlling various water bodies, including but not limited to the following areas:
1. Factory boiler water quality monitoring: used to prevent the formation of scale, prevent equipment corrosion, and ensure equipment safety.
2. Groundwater monitoring: used to monitor groundwater parameters such as pH value, conductivity, temperature, etc., so as to detect and solve water quality problems in time.
3. River and lake monitoring: used to monitor the water quality of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, so as to take timely pollution control measures.
4. Ocean monitoring: used to monitor the water quality of the ocean, such as salinity, dissolved oxygen, temperature and other parameters, so as to timely detect and control marine pollution.
5. Sewage treatment: used to monitor sewage water quality parameters, such as pH, COD, ammonia nitrogen, etc., in order to control and adjust the sewage treatment process.
6. Industrial production: used to monitor water quality in industrial production processes, such as pH, conductivity, dissolved oxygen and other parameters, so as to adjust the process in time and ensure product quality.
7. Water plant: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water to ensure the safety and hygiene of tap water.
8. Scientific research: used for water quality monitoring in the field of scientific research, such as lake eutrophication, climate change, etc.
3. Technical Features of Water Hardness Tester
1. High reliability: suitable for long-term work in the field environment, stable measurement and strong anti-interference ability.
2. Flexible and portable: Each probe can be freely combined, replaced independently, and plug and play.
3. Scalability: Various sensors can be freely combined.
4. Multiple applications: on-site rapid measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water, and urban pipe network water.
5. Tough shell: ABS+PC material, corrosion-resistant, can work normally for a long time.
6. Compact structure: can be installed in small places.
7. Communication connection: RS485 expansion interface, master/slave interface isolation and independent communication.
4. Technical Parameters of Water Hardness Tester
Display Output | 4.3-inch touch screen with strong LED backlight, can be operated under direct sunlight |
power supply | DC power supply: DC12V |
Power consumption | The power consumption of the instrument is about 12V/1W |
Sound Output | buzzer |
Communication Protocol | Standard RS485 Modbus-RTU protocol and device master/slave transmission channel support |
Main Materials | ABS+PC material |
Storage temperature | -20 to 70°C |
Operating temperature | -10 to 50°C |
Protection level | IP65 |
size | 175mm*140mm*49mm(length×width×height) |
weight | About 0.5KG |
5. Water Hardness Tester Sensor Configuration (optional)
Serial number | name | Measuring range | principle | Measurement accuracy | Configuration | Remark |
1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | ||
2 | pH | 0~14 (ph) | Electrochemistry (Salt Bridge) | ± 0.1PH | ||
3 | ORP | -1500mv~1500mv | Electrochemistry (Salt Bridge) | ± 6mv | ||
4 | Conductivity | 0~5000uS/cm | Contact electrode method | ± 1.5% | ||
5 | Turbidity | 0~40NTU (low turbidity) | Scattered light method | ± 1% | Optional | |
0~1000NTU (medium turbidity) | Scattered light method | ± 1% | ||||
0~3000NTU (high turbidity) | Scattered light method | ± 1% | ||||
6 | Dissolved oxygen | 0~20mg/L | Fluorescence lifetime method | ± 2% | ||
7 | Ammonia nitrogen | 0~100mg/l | Ion Selective Electrode Method | ±1mg | ||
8 | Suspended Matter | 0~2000mg/L | Scattered light method | ±5% (depending on sludge homogeneity) | ||
9 | Residual chlorine | 0~5.00 mg/L | Ion Selective Electrode Method | ±5% of reading | ||
10 | Chloride ion | 0-3500.0mg/L | Ion Selective Electrode Method | ±5% | ✔ | |
11 | Total hardness | 0~1000.0mg/L | Ion Selective Electrode Method | ±10% of reading | ✔ | |
12 | cod | 0~500mg/L | UV254 absorption method | ±5% | COD and chlorophyll are equipped with automatic cleaners to prevent biological attachment and avoid light window pollution to ensure long-term monitoring is still stable; the automatic cleaning time and cleaning times can be set, and the power consumption is 0.7W | |
13 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 |
本文地址:https://fengtusz.com/On-line-Water-Quality-Analysis/Water-Hardness-Tester.html
- Previous Article :Water Hardness Analyzer
- Next Article:no more
Related article
-
Waterlogging Monitors: Ensuring Safety in Urban Areas
2024-10-25 -
What are crop growth monitoring instruments?
2024-04-30 -
Agricultural Weather Stations: Monitoring Agricultural Microclimate
2024-09-19 -
Agrometeorological stations make agriculture smarter
2024-08-09 -
Installation of Agricultural meteorological stations in farmland
2024-08-26 -
Reservoir Level and Flow Monitoring System Helps Flood Control and Drought Relief
2024-05-29 -
Small automatic weather stations reduce agricultural losses
2024-03-12 -
Water Quality Monitor: The Core Instrument for Assessing and Safeguarding Water Resources
2024-11-21