Product Center
-
Hydrological equipment monitoring station
-
Water Quality Monitor Sensor
-
Plant protection equipment
-
Food Testing Equipment
- FT - LS1: Precision in Soil Erosion Monitoring
- Flexible Soil Moisture Monitoring Stations: Tailored for Agricultural Diversity
- The Significance of Water Quality Monitoring in River Restoration Projects
- Rice Seedling Disease Monitor: A Powerful Tool for Bakanae Disease Management
- Drainage Pipeline Monitoring with FT - PS1
- The Working Principle and Wide Applications of Radar Flow Meters
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Tel, Whatsapp:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Pool and Spa Water Quality Monitoring
Model:FT-YC06
Brand:fengtu
Related products
Product details
1. Pool and Spa Water Quality Monitoring Product Introduction
Pool and Spa Water Quality Monitoring Pool water temperature, ph, residual chlorine, turbidity, dissolved oxygen, orp six parameters, widely used in swimming venues, schools and so on!YC06 Online Pool and Spa Water Quality Monitoring is an instrument that can monitor water temperature, pH, residual chlorine, turbidity, dissolved oxygen, and ORP online. It integrates the corresponding sensors and measurement module communication storage, and can quickly and accurately record key parameters in the water body. At the same time, the instrument supports the expansion of multi-parameter water quality sensors, including but not limited to pH value, dissolved oxygen (DO), conductivity, turbidity, temperature, ammonia nitrogen, etc., which can be combined and configured according to different needs and applications, record and store historical monitoring data, alarm history records, and support historical data export.xlsx. The RS485 interface supports the MODBUS-RTU communication protocol to facilitate users to communicate freely with PLC, DCS, configuration software, DTU and other devices to connect and transmit data.
2. Pool and Spa Water Quality Monitoring Application Areas
Online Pool and Spa Water Quality Monitoring is widely used in the monitoring and control of various water bodies, including but not limited to the following areas:
1. Swimming pool water quality monitoring: used to monitor swimming pool water quality such as water temperature, pH, residual chlorine, turbidity, dissolved oxygen, ORP, etc., in order to ensure the health of swimmers.
2. Groundwater monitoring: used to monitor groundwater parameters such as pH value, conductivity, temperature, etc., so as to detect and solve water quality problems in time.
3. River and lake monitoring: used to monitor the water quality of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, so as to take timely pollution control measures.
4. Ocean monitoring: used to monitor the water quality of the ocean, such as salinity, dissolved oxygen, temperature and other parameters, so as to timely detect and control marine pollution.
5. Sewage treatment: used to monitor sewage water quality parameters, such as pH, COD, ammonia nitrogen, etc., in order to control and adjust the sewage treatment process.
6. Industrial production: used to monitor water quality in industrial production processes, such as pH, conductivity, dissolved oxygen and other parameters, so as to adjust the process in time and ensure product quality.
7. Water plant: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water to ensure the safety and hygiene of tap water.
8. Scientific research: used for water quality monitoring in the field of scientific research, such as lake eutrophication, climate change, etc.
3. Pool and Spa Water Quality Monitoring Technical Features
1. High reliability: suitable for long-term work in the field environment, stable measurement and strong anti-interference ability.
2. Flexible and portable: Each probe can be freely combined, replaced independently, and plug and play.
3. Scalability: Various sensors can be freely combined.
4. Multiple applications: on-site rapid measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water, and urban pipe network water.
5. Tough shell: ABS+PC material, corrosion-resistant, can work normally for a long time.
6. Compact structure: can be installed in small places.
7. Communication connection: RS485 expansion interface, master/slave interface isolation and independent communication.
4. Pool and Spa Water Quality Monitoring Technical Parameters
Display Output | 4.3-inch touch screen with strong LED backlight, can be operated under direct sunlight |
power supply | DC power supply: DC12V |
Power consumption | The power consumption of the instrument is about 12V/1W |
Sound Output | buzzer |
Communication Protocol | Standard RS485 Modbus-RTU protocol and device master/slave transmission channel support |
Main Materials | ABS+PC material |
Storage temperature | -20 to 70°C |
Operating temperature | -10 to 50°C |
Protection level | IP65 |
size | 175mm*140mm*49mm(length×width×height) |
weight | About 0.5KG |
5. Pool and Spa Water Quality Monitoring Sensor Configuration (Optional)
Serial number | name | Measuring range | principle | Measurement accuracy | Configuration | Remark |
1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | ✔ | |
2 | pH | 0~14 (ph) | Electrochemistry (Salt Bridge) | ± 0.1PH | ✔ | |
3 | ORP | -1500mv~1500mv | Electrochemistry (Salt Bridge) | ± 6mv | ✔ | |
4 | Conductivity | 0~5000uS/cm | Contact electrode method | ± 1.5% | ||
5 | Turbidity | 0~40NTU (low turbidity) | Scattered light method | ± 1% | ✔ | Optional |
0~1000NTU (medium turbidity) | Scattered light method | ± 1% | ||||
0~3000NTU (high turbidity) | Scattered light method | ± 1% | ||||
6 | Dissolved oxygen | 0~20mg/L | Fluorescence lifetime method | ± 2% | ✔ | |
7 | Ammonia nitrogen | 0~100mg/l | Ion Selective Electrode Method | ±1mg | ||
8 | Suspended Matter | 0~2000mg/L | Scattered light method | ±5% (depending on sludge homogeneity) | ||
9 | Residual chlorine | 0~5.00 mg/L | Ion Selective Electrode Method | ±5% of reading | ✔ | |
10 | Chloride ion | 0-3500.0mg/L | Ion Selective Electrode Method | ±5% | ||
11 | Total hardness | 0~1000.0mg/L | Ion Selective Electrode Method | ±10% of reading | ||
12 | cod | 0~500mg/L | UV254 absorption method | ±5% | COD and chlorophyll are equipped with automatic cleaners to prevent biological attachment and avoid light window pollution to ensure long-term monitoring is still stable; the automatic cleaning time and cleaning times can be set, and the power consumption is 0.7W | |
13 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 |
本文地址:https://fengtusz.com/On-line-Water-Quality-Analysis/Pool-and-Spa-Water-Quality-Monitoring.html
- Previous Article :Hospital water quality monitoring
- Next Article:Aquaculture Water Quality Monitoring
Related article
-
Role of water detection systems
2024-04-07 -
Vegetable base Agricultural Environment Monitoring System
2024-08-23 -
Spore Catcher: A Powerful Tool for Monitoring Plant Fungal Diseases
2024-09-18 -
Water Quality Monitor: The Core Instrument for Assessing and Safeguarding Water Resources
2024-11-21 -
Radar Flow Monitoring System for Flood Prevention
2024-05-17 -
Multi-functional Pocket Handheld Weather Meter, Pocket Weather Treasure
2024-07-24 -
Advantages of drone applicators
2024-07-05 -
Weather stations for transmission lines to prevent power supply obstacles to disasters
2024-05-09