Product Center
-
Hydrological equipment monitoring station
-
Water Quality Monitor Sensor
-
Plant protection equipment
-
Food Testing Equipment
- How to measure the moisture content of plant soil?
- Small automatic water quality monitoring system Real-time Monitoring of Water Temperature, Conductivity, pH, and Multiple Water Quality Parameters
- Groundwater Monitoring Application Scope and Measurement Performance
- Rainfall Monitoring employs K-band radar for non-contact monitoring of rainfall and water level
- Wheat Fusarium Head Disease Monitoring System: A Wheat Disease Prediction Solution Based on Spore Capture and Built-in Model
- Water quality monitoring system: Integrated Water Quality Analysis Equipment for Monitoring Water Temperature, Conductivity, pH, and Dissolved Oxygen
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Tel, Whatsapp:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Water Quality Monitoring System
Model:FT-ZS03
Brand:fengtu
Related products
Product details
1.Water Quality Monitoring System Product Introduction
The Water Quality Monitoring System mainly implements online monitoring and early warning for turbidity, dissolved oxygen (DO), PH, COD and temperature of water quality.Water Quality Monitoring SystemZS03 is an instrument that can measure multiple water quality parameters at the same time. It integrates multiple sensors and measurement module communication storage, and can quickly and accurately record multiple key parameters in the water body. Including but not limited to water temperature, conductivity, pH, etc., it can be combined and configured according to different needs and applications, record and store historical monitoring data, alarm history records, and support historical data export.xlsx. The RS485 interface supports MODBUS-RTU communication protocol to facilitate users to freely communicate with PLC, DCS, configuration software, DTU and other devices to connect and transmit data.
2. Application fields of Water Quality Monitoring System
ZS03Water Quality Monitoring System is widely used in monitoring and controlling various water bodies, including but not limited to the following areas:
1. Water plant: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water to ensure the safety and hygiene of tap water.
2. Groundwater monitoring: used to monitor groundwater parameters such as pH value, conductivity, temperature, etc., so as to detect and solve water quality problems in time.
3. River and lake monitoring: used to monitor the water quality of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, so as to take timely pollution control measures.
4. Ocean monitoring: used to monitor the water quality of the ocean, such as salinity, dissolved oxygen, temperature and other parameters, so as to timely detect and control marine pollution.
5. Sewage treatment: used to monitor sewage water quality parameters, such as pH, COD, ammonia nitrogen, etc., in order to control and adjust the sewage treatment process.
6. Industrial production: used to monitor water quality in industrial production processes, such as pH, conductivity, dissolved oxygen and other parameters, so as to adjust the process in time and ensure product quality.
7. Scientific research: used for water quality monitoring in the field of scientific research, such as lake eutrophication, climate change, etc.
3. Technical Features of Water Quality Monitoring System
1. High reliability: suitable for long-term work in the field environment, stable measurement and strong anti-interference ability.
2. Flexible and portable: Each probe can be freely combined, replaced independently, and plug and play.
3. Scalability: Various sensors can be freely combined.
4. Multiple applications: on-site rapid measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water, and urban pipe network water.
5. Tough shell: ABS+PC material, corrosion-resistant, can work normally for a long time.
6. Compact structure: can be installed in small places.
7. Communication connection: RS485 expansion interface, master/slave interface isolation and independent communication.
4. Technical Parameters of Water Quality Monitoring System
| Display Output | 4.3-inch touch screen with strong LED backlight, can be operated under direct sunlight |
| power supply | DC power supply: DC12V |
| Power consumption | The power consumption of the instrument is about 12V/1W |
| Sound Output | buzzer |
| Protocol | Standard RS485 Modbus-RTU protocol and device master/slave transmission channel support |
| Main material | ABS+PC material |
| storage temperature | -20 to 70°C |
| Operating temperature | -10 to 50°C |
| Protection level | IP65 |
| size | 175mm*140mm*49mm(length×width×height) |
| weight | About 0.5KG |
5. Water Quality Monitoring System Product Dimensions
Water Quality Monitoring System Dimensions

6. Water Quality Monitoring System Sensor Configuration (optional)
| Serial number | name | Measuring range | Measuring principle | measurement accuracy | Is it standard? | Remark |
| 1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | ✔ | |
| 2 | pH | 0~14 (ph) | Electrochemistry (Salt Bridge) | ±0.1PH | ✔ | |
| 3 | ORP | -1500mv~1500mv | Electrochemistry (Salt Bridge) | ±6mv | ||
| 4 | Conductivity | 0~5000uS/cm | Contact electrode method | ±1.5% | ✔ | |
| 5 | Turbidity | 0~40NTU (low turbidity) | Scattered light method | ±1% | Low turbidity can be customized | |
| 0~1000NTU (medium turbidity) | Scattered light method | ±1% | Medium turbidity can be customized | |||
| 0~3000NTU (high turbidity) | Scattered light method | ±1% | ||||
| 6 | Dissolved oxygen | 0~20mg/L | Fluorescence lifetime method | ±2% | ||
| 7 | Ammonia nitrogen | 0-1000.00mg/L (default) 0-100.00mg/l/ (customizable) | Ion Selective Electrode Method | 10% of reading, ±0.5℃ | ||
| 8 | cod | 0~500mg/L | UV254 absorption method | ±5% | ||
| 9 | Suspended Matter | 0~2000mg/L | Scattered light method | ±5% (depending on sludge homogeneity) | ||
| 10 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 |
This paper addresses:https://fengtusz.com/On-line-Water-Quality-Analysis/Water-Quality-Monitoring-System.html
- Previous Article :online ammonia nitrogen analyzer
- Next Article:Online Water Quality Monitoring
Related article
-
Why Portable Water Quality Meters Are Indispensable for Modern Water Monitoring
2025-02-24 -
Drainage Pipeline Monitoring with FT - PS1
2025-01-13 -
High-Performance GNSS Receivers for Precision Positioning and Displacement Measurement" Chinese
2025-10-28 -
Differences between Ultrasonic and Mechanical Handheld Weather Stations
2025-03-11 -
Intelligent Water Conservancy Systems for Natural Disaster Early Warning
2024-11-06 -
Online Ammonia - Nitrogen Sensors: Pivotal Tools in Understanding, Measuring and Solving Ammonia - Nitrogen Issues
2025-02-18 -
FT-QJZ1 Tilt Acceleration Monitoring Station: Industrial-Grade 3-Axis Inclinometer
2025-10-22 -
Cloud-Based Temperature & Moisture Meter for Precision Farming
2025-06-12


Get a Free Quote