Product Center
-
Hydrological equipment monitoring station
-
Water Quality Monitor Sensor
-
Plant protection equipment
-
Food Testing Equipment
- Online water quality monitors are used for water quality monitoring in rivers, water treatment plants, and pipe networks
- Soil moisture monitoring equipment accurately captures data on changes in soil moisture and temperature
- The real-time water quality monitoring instrument achieves online early warning of water quality in the pipe network through multi-parameter sensors
- Soil Moisture Monitoring Equipment Enables All-Weather, Multi-Parameter Automatic Monitoring of Farmlands
- Soil Monitoring Equipment Enables Rapid, Integrated, Multi-Parameter Measurement of Soil Moisture Conditions
- Turbidimeters for Hydrological Monitoring Record Water Turbidity Changes via the Scattered Light Method
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Tel, Whatsapp:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

online ammonia nitrogen sensor
Model:FT-S5
Brand:fengtu
Product details
1.Application environment of online ammonia nitrogen sensor
online ammonia nitrogen sensor does not require reagents, online monitoring, direct installation, testing is fast, simple, accurate and economical.Used for ammonia nitrogen concentration in environmental water quality, it can meet the measurement requirements of ammonia nitrogen in most industrial environment applications.
2. Product Features of online ammonia nitrogen sensor
The built-in pH electrode can detect the pH of water and compensate for ammonia nitrogen in real time according to the pH concentration.
Signal output: RS485 (MODBUS)
The electrode is a composite electrode, which is composed of a working electrode and a reference electrode made of polyvinyl chloride and ion active substances.
Internal signal isolation technology, strong anti-interference ability.
It has the characteristics of fast and accurate measurement and easy operation.
3. Technical parameters of online ammonia nitrogen sensor
| sensor | Ammonia nitrogen | PH |
| Measuring principle | Ion Selective Electrode Method | Electrochemistry (Salt Bridge) |
| Measuring range | 0-1000.00mg/L (default) 0-100.00mg/l (customizable) | 0-14.00 (PH) |
| Measurement accuracy | 10% of reading, ±0.5℃ | 0.01PH, ±0.01℃ |
| Response time | 5min | About 10s (98% flowing liquid) About 15s (98% stationary liquid) |
| Algorithm compensation | Temperature compensation, pH compensation | Temperature compensation |
| Shell material | ABS | |
| Cable length | Standard 5m | |
| Supply voltage | 12-24VDC (0.4W@12V) | |
| Measurement environment | Temperature 0~50℃ (no freezing), < 0.2MPa | |
| Waterproof grade | IP68 | |
| Installation | Immersion installation, NPT3/4 thread | |
4. Online ammonia nitrogen sensor maintenance and care
Before testing, remove the protective covers of the ammonium ion measuring electrode and the pH electrode. The electrodes should be soaked in clean water for 2 hours. After activation, they should be cleaned in deionized water and then tested. If the electrodes are not used for a long time (more than two weeks), they should be stored dry, and the sensing elements of the electrodes should be covered with protective caps. In order to obtain high-precision results, it is recommended to repeat these steps: remove the electrodes from the standard solution, wash, dry, and then immerse them in the standard solution (immerse for at least 2 minutes to obtain stable readings) to ensure that the electrodes are properly rinsed and pretreated.
Check whether the terminal is dry. If there is any stain, wipe it with anhydrous alcohol and use it after drying. Avoid long-term immersion in distilled water or protein solution, and prevent contact with silicone grease. The PVC film of the electrode that has been used for a long time may become translucent or have sediment. In this case, it can be rinsed with distilled water (or deionized water). If the electrode has been used for a long time and measurement errors occur, it must be calibrated.
This paper addresses:https://fengtusz.com/Water-Quality-Sensors/online-ammonia-nitrogen-sensor.html
- Previous Article :On-line ph sensor
- Next Article:Online ORP Sensor
Related article
-
What is the approximate weight and size of the current water quality monitoring buoys?
2024-05-27 -
Waterlogging monitoring system to prevent urban flooding
2024-02-27 -
Rice Sheath Blight Monitoring System FT-SD6
2024-10-31 -
4 Water Quality Monitor Equipment ,Check it out!
2024-08-13 -
Agrometeorological observation instruments
2024-06-17 -
Urban drainage monitoring stations to prevent urban flooding
2024-04-15 -
Differences between Ultrasonic and Mechanical Handheld Weather Stations
2025-03-11 -
Radar Flow Monitoring System for Flood Prevention
2024-05-17


Get a Free Quote