Product Center
-
Hydrological equipment monitoring station
-
Water Quality Monitor Sensor
-
Plant protection equipment
-
Food Testing Equipment
- FT-WS1 Soil Temperature and Moisture Meter: A Key Tool for Precision Agriculture and Environmental Monitoring
- FT-WY2 GNSS Monitoring Station: Delivering Millimeter-Level Precision for Deformation Monitoring
- FT-LS5+ Hand-Held Radar Current Meter: Enabling Safe and Non-Contact Flow Measurement
- GNSS Monitoring Station: A Reference Station for High-Precision Displacement Monitoring
- Fengtu Soil Moisture Monitor: Precision Dielectric Sensing for Advanced Agriculture
- GNSS Surface displacement monitoring system: For Engineering Safety and Geological Disaster Early Warning
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Tel, Whatsapp:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

African swine fever laboratory diagnostics
Model:FT-CW16H
Brand:fengtu
Related products
Product details
African swine fever laboratory diagnostics instrument basic structure
African swine fever laboratory diagnostics is a field-application African swine fever diagnostic test device that is essential for diagnosing ASF and controlling it in a timely manner.African swine fever laboratory diagnostics is an instrument for real-time detection of reactions. It mainly consists of a gene amplification thermal cycle system, a fluorescence real-time detection system, a microcircuit control system, a computer and application software. Two of the core functional modules are: thermal circulation system and fluorescence real-time detection system. The working principle of the gene amplification thermal cycle system is basically the same as that of the traditional gene amplification instrument. It uses semiconductor heating and cooling to complete the thermal cycle process. The fluorescence detection system mainly consists of fluorescence excitation components, optical signal transmission components, fluorescence detection components, and control systems.
African swine fever laboratory diagnostics instrument technical specifications
The "///" symbol indicates that the national standard currently does not define this indicator or mandatory requirement.
| Indicator name | CW16H | CW32H | CW48H | |
| Appearance | ||||
| Overall dimensions | 235mm*385mm*175mm (width*depth*height) | |||
| weight | 5.6kg | 5.7kg | 5.8Kg | |
| Electrical parameters | ~220V/50Hz, 255W | |||
| Data interface | USB 2.0 *2 (two on the right) | |||
| Environmental parameters | ||||
| Operating conditions | Temperature: 10-30℃, humidity: 20%~80% | |||
| Shipping and storage conditions | Temperature: -20~55℃, humidity: 20%~80% | |||
| altitude | <2500 meters | |||
| Noise level | A-weighted, <60dB | |||
| Sample parameters | ||||
| sample size | 16*0.2mL | 32*0.2mL | 48*0.2mL | |
| Test tube type | Single tube, eight row test tubes | |||
| sample volume | 15-100uL | |||
| Temperature characteristics | ||||
| Heating/cooling method | Semiconductor heating/cooling | |||
| temperature range | 4℃-99℃ | |||
| Maximum heating rate | ≥3.5℃/s | |||
| average heating rate | ≥2.5℃/s | |||
| Maximum cooling rate | ≥3.5℃/s | |||
| average cooling rate | ≥2.5℃/s | |||
| Temperature control accuracy | ≤±0.01℃ | |||
| Temperature accuracy | ≤±0.1℃ | |||
| temperature uniformity | ≤±0.3℃ | |||
| Optical properties | ||||
| Number of fluorescence detection channels | 4 channels | |||
| Light emitting device | High brightness LED | |||
| lighting devices | High sensitivity, high signal-to-noise ratio photodiode | |||
| Adapter probe or dye | First channel: 470/520 FAM, SYBR Green | |||
| Second channel: 530/570 HEX, JOE, VIC | ||||
| Third channel: 580/610 ROX, CY3.5, Texas-Red | ||||
| Fourth channel: 630/670 CY5 | ||||
| Detection sensitivity | 1 copy | |||
| Linear detection range | 100~1010 copies | |||
| linear correlation coefficient | ≥0.999 | |||
| Channel crosstalk | No crosstalk | |||
| Test repeatability | ≤1.0% | |||
Main application areas of African swine fever laboratory diagnostics instruments
Foodborne pathogen testing
food safety
Animal and plant origin testing
Plant Science and Agricultural Biotechnology
Gene mutations and polymorphisms
animal diseases
basic scientific research
water body monitoring
Pathogen nucleic acid detection
GMO testing
Animal epidemic surveillance
Food hygiene and quarantine
Customs import and export quarantine
This paper addresses:https://fengtusz.com/African-Swine-Fever-Virus/African-swine-fever-laboratory-diagnostics.html
- Previous Article :Pet virus detector
- Next Article:African swine fever virus detection
Related article
-
List of instruments and equipment for river field monitoring stations
2024-02-20 -
At a Glance: Moisture Monitoring System for Instant Field Insights
2025-09-17 -
Digital Farm Monitor, a hand-held weather station
2024-08-02 -
High-standard farmland construction equipment - crop growth (seedling) monitoring and diagnostic instrument
2024-05-28 -
Rodent Intelligent Cyclic Trap and Control Device
2024-05-16 -
IoT-based Soil Moisture Monitors: Paving the Way for Precision Vegetable Farming
2025-01-08 -
Installation of Agricultural meteorological stations in farmland
2024-08-26 -
Leveraging Surface Displacement Monitoring System for Secure Mineral Mining
2025-04-07


Get a Free Quote






