Product Center
-
Hydrological equipment monitoring station
-
Water Quality Monitor Sensor
-
Plant protection equipment
-
Food Testing Equipment
- FT - LS1: Precision in Soil Erosion Monitoring
- Flexible Soil Moisture Monitoring Stations: Tailored for Agricultural Diversity
- The Significance of Water Quality Monitoring in River Restoration Projects
- Rice Seedling Disease Monitor: A Powerful Tool for Bakanae Disease Management
- Drainage Pipeline Monitoring with FT - PS1
- The Working Principle and Wide Applications of Radar Flow Meters
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Tel, Whatsapp:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
ATP Cleaning Verification
Model:FT-ATP
Brand:fengtu
Related products
Product details
ATP Cleaning Verification Product Introduction:
ATP Cleaning Verification is suitable for rapid detection of microorganisms in food and drinking water, and rapid detection of tableware cleanliness.This device is a brand new upgraded product, with a large touch screen instead of traditional buttons. The operation uses a biochemical reaction method to detect the ATP content. The ATP fluorescence detector is based on the principle of firefly luminescence and uses the "luciferase-luciferin system" to quickly detect adenosine triphosphate (ATP). The ATP swab contains a reagent that can lyse the cell membrane, which can release ATP in the cell and react with the specific enzyme contained in the reagent to produce light. The luminescence value is then detected by a fluorescent illuminometer. The number of microorganisms is proportional to the luminescence value. Since all living cells contain a constant amount of ATP, the ATP content can clearly indicate the amount of microorganisms and other biological residues in the sample, which is used to judge the sanitary conditions.
ATP Cleaning Verification Instrument Features:
Practicality——Upper and lower limits can be set according to environmental testing requirements to achieve rapid data evaluation and early warning, and rapid screening of surface cleanliness.
High sensitivity - 10-15~10-18 mol
Fast speed - conventional culture method takes more than 18-24 hours, while ATP only takes a dozen seconds.
Feasibility - There is a clear correlation between the number of microorganisms and the ATP contained in the microorganisms. By testing the ATP content, the number of microorganisms in the reaction can be indirectly obtained.
Operability - Traditional culture methods need to be operated by trained technicians in the laboratory; while ATP rapid cleanliness detection is very easy to operate and can be performed on-site by general staff with simple training.
Better experience - the test sleeve adopts a plug-in and flexible design, which can be cleaned regularly and used for a long time to extend the life of the instrument.
ATP Cleaning Verification main parameters:
1. Display screen: 3.5-inch high-precision graphic touch screen
2. Processor: 32-bit high-speed data processing chip
3. Detection accuracy: 1×10-18mol
4. Detection range: 0 to 9999 RLUs
5. Detection time: 15 seconds
6. Detection interference: ±5﹪ or ±5 RLUs
7. Operating temperature range: 5℃ to 40℃
8. Operating humidity range: 20-85﹪
9. ATP recovery rate: 90-110%
10. Detection mode: RLU, coliform group screening
11. 50 user ID settings
12. The number of result limits that can be set: 251
13. Automatically judge whether it is qualified or not
14. Automatic statistics of pass rate
15. Built-in self-calibration light source
16. Self-check after 30 seconds of power on
17. Equipped with miniUSB interface, the results can be uploaded to PC
18. Equipped with special software to drive USB disk instead of traditional CD
19. Instrument size (W×H×D): 188 mm×77 mm×37 mm
20. Use rechargeable lithium battery to avoid battery replacement
21. Standby status (20℃): 6 months
22. Chinese operation manual
23. Stable liquid luciferase
24. Moistened integrated collection swab
Fengtu ATP fluorescence detector has a wide range of uses and can be used in many industries such as food, medical and health, medicine, daily chemicals, papermaking, industrial water treatment, national defense and environmental protection, water administration, customs entry-exit quarantine and other law enforcement departments.
Random configuration: ATP fluorescence detector (handheld) host, aluminum alloy suitcase, drive USB disk, PC data cable, data analysis software, Chinese operation manual
本文地址:https://fengtusz.com/ATP-Testing-Meter/ATP-Cleaning-Verification.html
- Previous Article :no more
- Next Article:no more
Related article
-
Advantages of drone applicators
2024-07-05 -
Heavy Metal Pollution in Water: From Source to Solution
2024-12-27 -
Agricultural Four Conditions Monitoring System: Empowering Modern Agriculture
2024-10-10 -
What are crop growth monitoring instruments?
2024-04-30 -
Introduction of Fengtu Small Portable Automatic Weather Station
2024-07-23 -
What does hydrological monitoring equipment do?
2024-02-29 -
Functions and Benefits of Automatic Soil Monitoring System in Modern Agriculture
2024-12-10 -
Agro-meteorological observation instruments, agricultural auxiliary research tools
2024-04-09