Product Center
-
Hydrological equipment monitoring station
-
Water Quality Monitor Sensor
-
Plant protection equipment
-
Food Testing Equipment
- FT-WS1 Soil Temperature and Moisture Meter: A Key Tool for Precision Agriculture and Environmental Monitoring
- FT-WY2 GNSS Monitoring Station: Delivering Millimeter-Level Precision for Deformation Monitoring
- FT-LS5+ Hand-Held Radar Current Meter: Enabling Safe and Non-Contact Flow Measurement
- GNSS Monitoring Station: A Reference Station for High-Precision Displacement Monitoring
- Fengtu Soil Moisture Monitor: Precision Dielectric Sensing for Advanced Agriculture
- GNSS Surface displacement monitoring system: For Engineering Safety and Geological Disaster Early Warning
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Tel, Whatsapp:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Surface Water Quality Monitoring
Model:FT-DBS05
Brand:fengtu
Related products
Product details
1. Surface Water Quality Monitoring Product Introduction
Surface Water Quality Monitoring can be freely combined with a variety of water quality intelligent electrodes, widely used for surface water, river monitoring, lake monitoring.DBS05 Online Surface Water Quality Monitoring is an instrument that can monitor water temperature, pH, dissolved oxygen, turbidity, and conductivity online. It integrates the corresponding sensors and measurement module communication storage, and can quickly and accurately record key parameters in the water body. At the same time, the instrument supports the expansion of water quality multi-parameter sensors, including but not limited to pH, dissolved oxygen (DO), conductivity, turbidity, temperature, ammonia nitrogen, etc., which can be combined and configured according to different needs and applications, record and store historical monitoring data, alarm history records, and support historical data export.xlsx. The RS485 interface supports the MODBUS-RTU communication protocol to facilitate users to communicate freely with PLC, DCS, configuration software, DTU and other devices to connect and transmit data.
2. Application fields of Surface Water Quality Monitoring
Online Surface Water Quality Monitoring is widely used in the monitoring and control of various water bodies, including but not limited to the following areas:
1. Water plant: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water to ensure the safety and hygiene of tap water.
2. Groundwater monitoring: used to monitor groundwater parameters such as pH value, conductivity, temperature, etc., so as to detect and solve water quality problems in time.
3. River and lake monitoring: used to monitor the water quality of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, so as to take timely pollution control measures.
4. Ocean monitoring: used to monitor the water quality of the ocean, such as salinity, dissolved oxygen, temperature and other parameters, so as to timely detect and control marine pollution.
5. Sewage treatment: used to monitor sewage water quality parameters, such as pH, COD, ammonia nitrogen, etc., in order to control and adjust the sewage treatment process.
6. Industrial production: used to monitor water quality in industrial production processes, such as pH, conductivity, dissolved oxygen and other parameters, so as to adjust the process in time and ensure product quality.
7. Scientific research: used for water quality monitoring in the field of scientific research, such as lake eutrophication, climate change, etc.
3. Technical Features of Surface Water Quality Monitoring
1. High reliability: suitable for long-term work in the field environment, stable measurement and strong anti-interference ability.
2. Flexible and portable: Each probe can be freely combined, replaced independently, and plug and play.
3. Scalability: Various sensors can be freely combined.
4. Multiple applications: on-site rapid measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water, and urban pipe network water.
5. Tough shell: ABS+PC material, corrosion-resistant, can work normally for a long time.
6. Compact structure: can be installed in small places.
7. Communication connection: RS485 expansion interface, master/slave interface isolation and independent communication.
4. Surface Water Quality Monitoring Technical Parameters
| Display Output | 4.3-inch touch screen with strong LED backlight, can be operated under direct sunlight |
| power supply | DC power supply: DC12V |
| Power consumption | The power consumption of the instrument is about 12V/1W |
| Sound Output | buzzer |
| Communication Protocol | Standard RS485 Modbus-RTU protocol and device master/slave transmission channel support |
| Main Materials | ABS+PC material |
| Storage temperature | -20 to 70°C |
| Operating temperature | -10 to 50°C |
| Protection level | IP65 |
| size | 175mm*140mm*49mm(length×width×height) |
| weight | About 0.5KG |
5. Surface Water Quality Monitoring Sensor Configuration (optional)
| Serial number | name | Measuring range | principle | Measurement accuracy | Configuration | Remark |
| 1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | ✔ | |
| 2 | pH | 0~14 (ph) | Electrochemistry (Salt Bridge) | ± 0.1PH | ✔ | |
| 3 | ORP | -1500mv~1500mv | Electrochemistry (Salt Bridge) | ± 6mv | ||
| 4 | Conductivity | 0~5000uS/cm | Contact electrode method | ± 1.5% | ✔ | |
| 5 | Turbidity | 0~40NTU (low turbidity) | Scattered light method | ± 1% | Optional | |
| 0~1000NTU (medium turbidity) | Scattered light method | ± 1% | ||||
| 0~3000NTU (high turbidity) | Scattered light method | ± 1% | ✔ | |||
| 6 | Dissolved oxygen | 0~20mg/L | Fluorescence lifetime method | ± 2% | ✔ | |
| 7 | Ammonia nitrogen | 0-1000.00mg/L (default) 0-100.00mg/l/ (customizable) | Ion Selective Electrode Method | 10% of reading, ±0.5℃ | ||
| 8 | Suspended Matter | 0~2000mg/L | Scattered light method | ±5% (depending on sludge homogeneity) | ||
| 9 | Residual chlorine | 0~5.00 mg/L | Ion Selective Electrode Method | ±5% of reading | ||
| 10 | Chloride ion | 0-3500.0mg/L | Ion Selective Electrode Method | ±5% | ||
| 11 | Total hardness | 0~1000.0mg/L | Ion Selective Electrode Method | ±10% of reading | ||
| 12 | cod | 0~500mg/L | UV254 absorption method | ±5% | COD and chlorophyll are equipped with automatic cleaners to prevent biological attachment and avoid light window pollution to ensure long-term monitoring is still stable; the automatic cleaning time and cleaning times can be set, and the power consumption is 0.7W | |
| 13 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 |
This paper addresses:https://fengtusz.com/On-line-Water-Quality-Analysis/Surface-Water-Quality-Monitoring.html
- Previous Article :Drinking water monitoring system
- Next Article:Hospital water quality monitoring
Related article
-
Life Detection Radar System:Penetrating Obstacles, Capturing Vital Signs, and Accelerating Life-Saving Efforts
2025-07-16 -
Introduction to the cloud platform and software for field weather monitoring systems
2024-03-20 -
Water Level Monitoring System: Working Principle, Application Scenarios and Core Advantages
2025-08-25 -
Online Water Quality Analyzer: Its Technologies, Functions and Wide Applications
2025-05-06 -
Rainfall monitoring system to track rainfall
2024-07-15 -
Intelligent Agricultural Automatic Weather Station Equipment Introduction
2024-04-28 -
Portable Ultrasonic Water Depth Meter: Enhancing Efficiency in Water Rescue and Underwater Environmental Assessment
2025-07-11 -
FT - LF2 Crack Monitor: Your Shield Against Geological Risks
2025-01-21


Get a Free Quote






